I.U.D Procedure Tray Catalog # 926/IUD
Convenient, disposable, sterile

Contains components for Intra Uterine Device (IUD) insertion procedure.

Pedicat™ Antiseptic gel: lubricates speculum and coats all around vaginal walls, creating safe aseptic environment.

Endofocus Forceps: including  gauze ball (Tupfer) for application of antiseptic.

Tenaculum Forceps: For cervical traction. Unique design grasps cervix in a single "snap-close" movement, minimizing pain.

 

Hysterometer/Uterine Sound:  Flexible and foldable round tipped rod with round front edge and moving disk to sound the uterus depth.




Endofocus Clip-Cut: Cuts and removes IUD guiding thread.
Unexposed safe blades in "closed" position.


 

Instructions for Use

  The use of this device is limited to those
   qualified in its use.

1.           Peel open sealed sterile pack.

2.           Remove yellow waste disposal bag (can be hung from edge of work surface).

3.           Inject/pour antiseptic solution*  into small compartment in the tray.

4.           Don sterile gloves *.

5.           Follow instructions printed on the Pedicat™ sachet to lubricate speculum* with antiseptic lubricating gel.

6.           Use speculum in conventional manner.

7.           Grip gauze ball by closing Endofocus Forceps jaws, exerting thumb pressure on the rear mechanism (see illustration “A”).

8.           Using Endofocus Forceps, immerse gauze ball in antiseptic solution and disinfect cervical area.

9.           Grip cervix edge in one "snap-close" movement with Endofocus Tenaculum Forceps.

10.       While withdrawing Endofocus Tenaculum Forceps to align the uterus, sound uterus depth by carefully inserting the Hysterometer/Uterine Sound.

11.       Adjust I.U.D and Hysterometer/Uterine Sound for matching length.

12.       Insert I.U.D.

13.       To remove Endofocus Tenaculum Forceps, open jaws by pulling “trigger” (see illustration “B”).

14.    Close the Endofocus Clip-Cut jaws by maintaining thumb pressure on the rear mechanism (see illustration “C”), insert the device into the vagina, in "closed jaws" position, when close to thread, release thumb pressure, insert thread between jaws and retain pressure to cut, remove Endofocus Clip-Cut in closed position with remains of thread.

15.       If necessary, excess guiding thread can be removed by using the Endofocus Forceps.

* Not included in tray

Packaging: 20 trays per case, 4 cases per shipping carton.